BAKU New stay Scanning Microscopes ba-009 electronic repair binocular microscope

FOB Reference Price:Get Latest Price
US $278-331.5 / Sets | 1 Set/Sets ba 009 Electronic Repair Digital Microscope (Min. Order)
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Guangdong, China (Mainland)
Brand Name:
BAKU, BAKU ba-009 Microscope
Model Number:
ba-009
Theory:
Biological Microscope
Drawtube:
Binocular
Color:
White+ Black
Vertical Resolution:
450 TV line
Pick-up Device:
1/3"
Signal/Noise ratio:
More than 46db
Number of Pixels:
(H)768*(V)494
Scanning System:
525 lines,60Field/Second
Item:
Stereo Fluorescent Electron Microscope Price Preferential
Minimum illumination:
YES
Gamma Characteristic:
0.45
Packaging & Delivery
Packaging Details
1 Set / 1 Individually Wrapped Small Box ; More Logistics, Please Contact
Port
GuangZhou (China)
Lead Time :
Within 3-5 days after get the payment

BAKU New stay Scanning Microscopes BA-009 electronic repair binocular microscope

 

Product Description
Modelba-009
Pick-up Device1/3"
Vertical Resolution450 TV line
Number of Pixels(H)768*(V)494
Scanning System525 lines,60Field/Second
White BalanceCan be switched between auto and hand white balance
Back light CompensationAuto
Signal/Noise ratio

More than 46db

Gamma Characteristic0.45
Minimum illumination2 Lux/Binocular microscope
Input voltage12V DC (9V-14V)
Power consumption1.85 or less
Total video magnification range18-117

 

 Maintenance : 

1)All lenses must be kept clean.Fine dust on the surface of the lens should be blown off with hand blower or wiped off gently with a soft lens tissue. 

2)Fingerprints or oil marked on it should be wiped off with a tissue moistened with a small amount of xylene or a 3:7 mixture of alcohol and other. 

3)Never use the organce solution to clean the other surface(especially the plastic surfaces).If necessary,please choose the neutral detergent. 

4)Don't take the microscope apart for fearing that it is damaged. 

5)After using,cover the microscope with the dust-cover provided and store it in a dry and clean place free from moisture to prevent dust.  

6)To keep the performace of the microscope.please check it periodically.The detail can be gotten from the agent nearby. 

 

 

 

New Product

 

Attention:

1. Be sure not to disassembly
        Random to disassembly can easily lead the instrument broken,Please do not random to disassembly any parts except this operation instruction mentioned can disassembly of parts.If find the instrument out-of-order,Please ask professional person to repair or direct to contact supplier.

 

2. Inspect the voltage 

1) Microscope base marked rated input voltage values.Pay attention to match the local service voltage.If the microscope use under un-nominal voltage,will be serious damage.
2) Power supply socket should earthing fine.

 

3. Prevent burn and fire 

1) during illumination,the bulb will be very hot.Be careful that do not touch your skin.to avoid burn.
2) change the bulb should after cooling 
3) to avoid fire,inflammable do not close to bulb.

 

4. Change the bulb 

1) to avoid electric shock and damage the instrument ,before change the bulb,should pull out the attaching plug.
2) only use specified halogen and fluorescence lamp tube.
3) should wear gloves or use protective jacket mantle the bulb,Your hand do not touch the glass of bulb.After changeing the bulb,use the clean cloth to dip in straight alcohol,then wipe off the fingerprint and splodge that showed on bulb.Otherwise bulbs can be easily broken and reduce the lightness.

 

5. Carry and place

         1) should turn off power switch before carry the microscope
       2) working environment requirement:  room tempreture: 0℃~40℃ / maximum relative humidity: 85%
         3) when use the microscope should avoid under sunlight perpendicular incidence
         4) avoid the microscope put on dust environment,If disuse,should coat on dust cover.
         5) the microscope thould placed in no vibrative place.

 

 

Main Product

Our Services

 

Company Information
FAQ

1. What is the minimum order quantity (MOQ) for products?
Generally according to the requirements of customers, no matter how many we can accept.

2. How long is the product warranty?
We guarantee 3 months for domestic customers; and 3 months for oversea customers but they bear the freight fee or repair some accessories for secondary purchase. 

3. What's the advantage of your products?
A: 11 years of experience in production and sales,with independent brand complete variety of products of repair industry. 

4. Are you accept OEM order?
Yes, of course, but we have quantity requirement, please feel free to contact our staff for details. 

5. What about delivery day?
For sample with existing products, delivery within 3 days; and for customer order products in great quantity, 7 to 15 days. Generally 20-30 days for customer OEM products.

6. How about terms of payment?
A: T/T, PayPal, Western Union, Money Gram, L/C, etc.